Wood Stoves

Wood Stoves

The hazards of heating with a wood stove include fires started by heat radiated or conducted by the stove, stove pipe or chimney to walls, floors and other combustible materials; fires started by sparks and glowing coals falling out of front loading stoves when opened, and fires started by flames leaking out of faulty chimneys or burning or glowing material coming out of the top of the chimney. A chimney flow reversal is also possible, leading to either flames or smoke coming out of the stove's air inlets.

Before installing, seek advice from your stove dealer, your local building inspector or fire department. And check with your insurance agent. The insurance company may have its own specifications for installation and, since you are changing the method of heating your home, your agent must be notified in order to maintain fire insurance coverage on your home.

The National fire Protection Association (NFPA) has developed standards for clearances from walls and ceilings that are the basis for many local building codes. (Vis. T1) All combustible materials, woodwork, unprotected walls, furniture, firewood, etc., should be no closer than 36 inches to a wood stove. A stove pipe should not be closer than 18 inches to an unprotected ceiling. These distances are important because wood that is, continually reheated will ignite at much lower temperatures than fresh wood. A new wall will start to burn at between 500 and 700 degrees F. If this wall is continually heated over a period of time the wood will dry and eventually may start to char because of radiant heat. The ignition temperature can drop to 200 to 250 degrees F. For this reason an improper wood stove installation becomes a potential time bomb.(Vis. 1) shows proper installation.

Wall Protection

A simple test will tell if you have enough clearance to an unprotected wall. Place your hand on the closest surface. If you can keep your hand there comfortably while the stove is operating, the location passes the test. If not, you need additional protection.

Spacing asbestos millboard or 28 gauge steel 1-inch away from the wall allows you to reduce the distance a stove can be placed from the wall. (Vis. 2) These materials absorb heat radiated from the stove and the spacing lets air circulate behind the panel and cool the area between the wall and the panel. The spacers should be made of non-combustible material. A 1- to 1 1/2-inch gap between the panel and floor and at the top of the panel is necessary to provide proper air flow. Asbestos millboard is different from asbestos cement board or asbestos transite board. Cement board or transite boards are both hard, slate-like panel materials designed as a name barrier. They provide little in terms of heat resistance and will conduct heat to any combustible surface to which they are attached. Asbestos millboard is a soft, lightweight panel product that can be easily cut with a saw or utility knife.

WARNING: Inhaling asbestos fibers may be harmful. The effect of long term exposure is not completely known. However, you should wear a protective mask when cutting asbestos products.

Since brick and stone are good conductors of heat, they offer little protection if placed against a combustible wall or have wood studs behind them. To be effective, bricks must be placed out at least 1-inch from the wall with air gaps at the top and bottom. You can provide these air gaps by using half bricks on the top and bottom row. Stoves can be placed as close as 12 inches from the brick facing if you provide an air space behind the brick.

An inexpensive and temporary way to protect a wall if you already have a stove installed closer than 36 inches to an unprotected wall is to provide a baffle. This baffle could be sheet metal, hardware cloth or cement board hung on metal brackets approximately 4 inches behind the stove.

Floor Protection

All floors on which stoves are installed, except concrete, must be protected from both heat of the fire and hot coals falling out when fuel is added. Metal with asbestos backing and asbestos millboard are non- combustible materials used for floor protection. Fireproof clay tile, slate, brick, colored pebbles and marble chips can be used alone only if they are mortared in place with no gaps. If they are not mortared or have gaps, then metal or asbestos millboard must be installed between them and a wood floor. A 2-inch layer of ashes or sand or bricks laid in the bottom of the stove helps to insulate the bottom of the stove and protect the floor. In general, 18 inches is enough clearance to protect the floor if it is covered by non-flammable material, such as a sheet of 24 gauge metal or brick or fireproof clay tile. If the stove legs are from 6 to 18 inches long, 24 gauge sheet metal laid over a 1/4-inch sheet of asbestos millboard is needed. Legs of 6 inches or less require 2 to 4 inches of hollow masonry laid to provide air circulation and covered by 24 gauge sheet metal. If the stove has no legs, provide a sturdy support to allow air circulation under the stove.

The floor protection should extend at least 12 inches beyond the sides and rear of the stove, and at least 18 inches beyond the stove front, to protect against falling embers and for loading wood or removing ashes.

Before installing heavy protection materials such as brick, check the floor to make sure it can handle the increased weight. You may want to reinforce the joists under the floor. Consult a carpenter if necessary.

Stove Pipe


This information is for educational purposes only. References to commercial products or trade names does not imply endorsement by MSU Extension or bias against those not mentioned. This information becomes public property upon publication and may be printed verbatim with credit to MSU Extension. Reprinting cannot be used to endorse or advertise a commercial product or company. This file was generated from data base 02 on 02/27/01. Data base 02 was last revised on 12/04/98. Please read our disclaimer for important information about using our site.

 
Related Articles
Refrigerator--Cleaning
Range Care
Range Cleaning
Conventional Oven Care
Conventional Oven Cleaning
Continuous-Clean Oven Care
Continuous-Clean Oven Cleaning
Self-Cleaning Oven Care
Self-Cleaning Oven Cleaning
Gas and Electric Cooktop Care
 
All Related Articles
 


Property Type   Single Family Condo/Townhouse Vacant Land Multi-Family
City Price Range $,000 to $,000
Subdivision Bedrooms
Fireplace Waterfront
Street Name:  Browse Bathrooms
Basement
Zips  Browse Garage
# of Cars to
Grade School  Browse Clear Floorplan Details
Junior High  Browse Clear Architectual Style
High School  Browse Clear Age of Home
 
Status     Active     Pending     Closed
 
Foreclosure    


Marco Amidei
Marco Amidei
888-32-Marco
 
My Saved Items
Become a HomesByMarco member
and you'll be able to:

» Save Searches
» Save Properties
» View Market Summaries
» Receive New Home Alerts
Sign Up for FREE!
Client Testimonials

Our HomesByMarco team has helped move
130 families in 2003,
159 families in 2004,
168 families in 2005.
169 families in 2006.
141 families in 2007.
117 families in 2008.
114 families in 2009.
98 families in 2010.

We sell a home every 2.56 days.

Client Testimonials
"Enthusiastic and prompt service. Very professional and sensitive to customer needs."
--Mukund Srinivasan & Nirupama Ramachandran

View More Testimonials